sat, 29-jan-2011, 14:27

Cold cabin

Cold cabin

Ever since I finished renovating the new cabin, we’ve been keeping it warm in the hope that we’ll find a renter for it. But once we passed the start of the semester at UAF, we essentially gave up looking and have been waiting out the winter to try renting it again. The place is heated by a oil-burning Toyotomi direct vent heater that was only a few months old when we bought the place because the previous heater had been stolen. In our house and the red cabin, we use a similar heater called a Monitor. In Fairbanks, “monitor” is the word people use to describe this style of direct vent heater. Unfortunately, MPI was purchased by Toyotomi and the line has been discontinued.

I’ve been trying to check on the new cabin every day, but I didn’t go over there on Thursday and when Nika and I went over there yesterday, the Toyo had quit working (WTF!?). I’d previously checked it around 4 PM on Wednesday, and finally got the heat back on at around 5 PM on Friday. It was 16°F in the cabin at that point. Over the course of those two days and one hour, the average outside temperature was -3.9°F. The cabin was 60°F when I left it on Wednesday, so it lost just under one degree per hour (although the heat loss is a function of the difference between internal and external temperature, so the heat loss isn’t linear). At that rate, it probably would have been above freezing if I’d checked on it on Thursday.

So mistake number one was not checking it every day. The heater had been so reliable thus far this winter that I got complacent.

Crawlspace icicle

Crawlspace icicle

Guess what mistake number two was? Thankfully I’d shut off the pump before closing the place up in fall, but there’s still at least 100 gallons of water in the tank in the bathroom, and water sitting in the pipes, pump and on-demand water heater. I went over there this morning to see if any of the pipes were cracked and if there was any water anywhere.

Initially there was no sign of damage except for a little water underneath the pump. After looking under the house (see the photo on the right), it’s clear that there’s a leak somewhere near the pump, and all the pressure left in the pressure tank pumped a few gallons of water onto the floor, where it found a way to get through the vinyl floor, the new subfloor I installed this summer, and down into the structure and eventually out the bottom of the cabin.

After fiddling with opening faucets, I eventually hit on some combination of open valves that released a vacuum near the hot water heater, and water started pouring out, so there’s a leak somewhere in the hot water heater as well as near or inside the pump. Later in the day I went back with an air compressor and forced air into the hot and cold water lines, opening and closing different faucets until I forced all the water out of the pipes.

Lessons learned: check on the heat every day, and if there won’t be anyone in there, make sure to blow out all the water lines. In spring I’ll be replacing the hot water heater and probably the pump. Hopefully the pressure tank and the washing machine weren’t damaged, but at least I don’t need to replace the water lines or the water tank.

tags: heat  new cabin  Toyo  water 